View Single Post
  #8  
Old April 4th 04, 06:49 PM
James M. Knox
external usenet poster
 
Posts: n/a
Default

"Richard Kaplan" wrote in
s.com:

I was with a student in one of our club Arrows. We put the gear down
and got green lights for the 2 mains, but not for the nose.


Would activating the emergency gear extension system have been an
option to extend the nose gear in case it were down but not fully
locked?


"Sort of..." Since the two mains were down and locked there was no
pressure left in the system. Pressing the emergency gear extension knob
does nothing but release pressure, and so nothing new would have happened.

The procedure would have been to RETRACT the gear (if possible), slow down,
pull the CB, and THEN push the emergency gear extension knob. If the pump
were failing, then this faster release of pressure might do the trick.
OTOH, if there were a mechanical problem, then there are any number of
hypothetical situations where it might not even come down as well as
before.

You pays yer dollahs, and takes yer chances! G

-----------------------------------------------
James M. Knox
TriSoft ph 512-385-0316
1109-A Shady Lane fax 512-366-4331
Austin, Tx 78721
-----------------------------------------------