View Single Post
  #5  
Old September 22nd 03, 04:51 AM
Craig
external usenet poster
 
Posts: n/a
Default

(Fitzair4) wrote in message ...
We have PVC in our full time shop for 23 years. Never a problem. Just clean
and seal all the joints right. Have 120 psi.

Larry


Been in lots of places that used it and seen lots of failures. You do
know that Sch 40 and 80 both have an ultimate tensile strength of
only 7400psi at 73 deg. F.,( black iron is about 10-15 times that )
and that by the time you get to around 90deg F., that is reduced by
almost 50%? By the time you run the numbers for the data given in ASTM
D1784, the code that your pvc pipe is rated by, when you do all the
required derates and apply all the safety factors required for sound
engineering practices, 1" PVC is rated to handle about 4psi working
pressure. It also might interest you, in that the code specifically
states that the rating is good for incompressible liquids only and
that pvc and cpvc are to never be used in a compressible gas system
without revising the pressure ratings to those found under ASME B31.3.

BTW...if you are a commerical shop, the use of pvc like this will get
you some nice little code violations if the inspectors ever look
notices it, or OSHA visits.

Craig C.