Pneumatics Question
John,
I don't think you can have more than 1 pneumatic (mechanical) vario
connected to any TE pressure source. Did you have this vario
configuration before you replaced your tubing?
If it's not too much trouble I would try testing each vario
individually, pinching off (or replacing) the Y connector under the
seat so only one vario is connected to the TE at a time.
ted/2NO
|