On Tuesday, May 14, 2013 4:24:26 PM UTC-7, WaltWX wrote:
I've used my Volkslogger (VL) for years. Lately, I've been unable to transfer or download IGC log files to my PC. I'm using various PC's (Desktop; notebooks, etc) to no avail.
With SeeYou Connection Wizzard and Streppla, using a USB Converter (usbconveters.com - model Ut-882)and custom cables, the LCD windows on the VL only shows "data-transfer ready!" with no further interaction to DL log files.. I've used all this equipment in the past and it worked perfectly. Started having this problem in March 2013 when I thought it was solved by updating the FTDI device driver for the converter. Apparently, that probably wasn't the root cause of my problem.
Today, I made up new cables... and that didn't solve the problem either.
Has anyone out there seen this failure mode on the VL?
Walt Rogers, WX
I would suspect the converter first. FTDI based converters do not have a good reputation for reliability and have suffered from driver problems in the past. I would never recommend them. You can try uninstalling and reinstalling the drivers again, or just give up and get a better converter. Here is a likely much better converter (I use them on PCs and Macs for lots of uses).
http://www.amazon.com/Tripp-Lite-USA.../dp/B0000VYJRY
Whether that fixes your problem or not who knows, but I'd never waste time with an FTDI chipset based converter.