PowerFLARM choking on too many targets?
On Tuesday, July 21, 2015 at 7:48:17 PM UTC+8, Dave Nadler wrote:
On Monday, July 20, 2015 at 10:52:41 PM UTC-4, Matt Herron Jr. wrote:
When there were more than about 5 targets being tracked by the PowerFLARM,
the FlarmView display started to reboot repeatedly and rapidly every few
seconds as if it were being power cycled. It behaved normally during the
task when there were just a few targets at most to display.
On landing there were again many targets in close proximity
and the FlarmVIew display started to reboot again.
Um, so why didn't you title your post:
"FlarmView choking on too many targets?"
Have you discussed this with LX and/or your LX dealer?
Certainly not the first time this has been reported!
Dave
When it initially happens there is no way to tell if it is being caused by the PowerFlarm or an issue with the Flarmview. All you see is the Flarmview cycling like it is losing power which comes from the PowerFlarm.
I was at Nephi and yes we did send info about issue to LX and spoke with dealers.
I reverted back to the previous Firmware on my Year old Flarmview and it worked fine. We tried that on a newer Flarmview and it would not work.
So as Matt indicated initially it is hard to tell if it is a Flarmview issue or a PowerFlarm one.
And up to this point I have not seen this reported anywhere and discussed in detail till now.
Hopefully there will be a fix soon