PowerFLARM choking on too many targets?
On Mon, 20 Jul 2015 19:52:36 -0700 (PDT), "Matt Herron Jr."
wrote:
.... text deleted
When there were more than about 5 targets being tracked by the
PowerFLARM, the FlarmView display started to reboot repeatedly
and rapidly every few seconds as if it were being power cycled.
It behaved normally during the task when there were just a few
targets at most to display. On landing there were again many
targets in close proximity and the FlarmVIew display started to
reboot again.
Has anyone experienced this? I don't know how to tell if it is the
Powerflarm's fault, recycling the power to the FlarmVIew display
or the FlarmView Display itself getting overwhelmed by so many targets.
Thoughts?
Will the FlarmView support a 57.6kB data rate? I know the Butterfly
display will, that is the rate I run mine at. Higher rate should
support more targets.
Insert the following into flarmcfg.txt
# Set baud rate on RJ45 to 57.6kB
$PFLAC,S,BAUD1,5
# Set baud rate on DB9 to 57.6kB
$PFLAC,S,BAUD2,5
Bob
|