Tim Newport-Peace[_3_]
external usenet poster
Posts: 9
CAI 302 date problem
At 13:07 03 May 2016,
wrote:
Google on the 302 Data Port User's Guide. I don't see any way to set a
dat=
e shown in that manual. It does mention another document called the
Secure=
BIOS User's Guide that may include such details but I've never been able
t=
o find a copy of that document anywhere.
RS
On Tuesday, May 3, 2016 at 2:46:06 AM UTC-5, wrote:
Dear All
The CLEAR LOG command in See You Moile works very easily so I wonder
can
=
SEE You mobile also e used to set the date and time in the Camridge 302
at
=
the start of a days flying? Anyone know what the command is and correct
sy=
ntax for the date and time?
See You mobile retains the command in a drop down menu so it would e
easy=
to do each day=20
=20
Thanks for your help
Martin =20
From what you say, it would seem that your problem lies in the Real Time
Clock on the GPS25 engine and not in Cambridge hardware.
Phil Schlosser at Clearnav should be able the replace the RTC battery and
reset the clock.
The problem is that the RTC forget which epoch (1024 weeks) it is in, the
rest of the Time comes from satellites.