View Single Post
  #43  
Old April 7th 20, 05:32 PM posted to rec.aviation.soaring
Dan Marotta
external usenet poster
 
Posts: 4,601
Default Battery switching without tears

Well then, I must be really confused.Â* If the switch was a BREAK before
MAKE, the equipment would be momentarily without power.Â* Some devices
can survive that, perhaps with internal capacitance, but others will
lose power momentarily.Â* This may or may not be an issue.

Inrush current seems to be a big bugaboo to some people and, in some
cases it is, but what is the time constant associated with the inrush?Â*
How much current are we talking about and for how long? People keep
talking about the high battery "charging" the low battery during the
milliseconds that they are in parallel. Theoretically, yes, practically,
hogwash.Â* The heat required to blow a fuse or burn a wire does not rise
instantaneously; there's counter EMF to reduce the current...Â* So many
details that meant a bunch when you were taking a test back in school
but, practically speaking, don't mean squat in this case.

So, switch your batteries and protect your circuits however you wish.Â*
I'll stick with my make before break switches.Â* I'll even report back
when something fails due to their use, but don't hold your breath.

On 4/6/2020 10:43 PM, 2G wrote:
On Monday, April 6, 2020 at 11:23:21 AM UTC-7, Dan Marotta wrote:
Tom,

Isn't the rotary panel switch in a Schleicher glider a make before break?

OK, I'll stop posting to this thread now.Â* My solution, which I've
relied on for years without ever losing a connection or blowing a fuse
seems to be too simple to be acceptable.

On 4/5/2020 7:45 PM, 2G wrote:
The glider, an ASH 31 Mi, is already wired with a battery selector switch for the avionics, and is the way to go. You definitely don't want to parallel Pb and LFP battery's accidentally.

Tom

--
Dan, 5J

Dan,

Think about it: if it were MAKE before BREAK I wouldn't have had this problem and sure as hell wouldn't post a solution to a non-existent problem.


--
Dan, 5J