If this is your first visit, be sure to check out the FAQ by clicking the link above. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below. |
|
|
Thread Tools | Display Modes |
#18
|
|||
|
|||
![]()
: The reason why all electric panels are becoming common is because
: electrical systems are more reliable than vacuum, and backup is easier to : provide for everything, a second battery. It also makes more sense to : unify around a single system, instead of having a hodge-podge of two : different systems. Easier is relative. Designing a truly redundant electrical system is nontrivial and expensive in both money, weight, and complexity. Strictly speaking, you should have dual alternators, dual busses with crossover breakers, etc, etc. It's not as simple as "throwing another battery" in the tail. If the system isn't designed properly or is improperly operated, a failed system can break the other system. The nice thing about the standard six-pack is that there's redundancy built into the instruments and sources. Yes, vacuum systems are less reliable, but short of something catastrophic, they are *completely* independent. It would probably be better to transition to an electric AI and vacuum TC as "standard equipment"... or maybe electric DG and vacuum TC. Still redundancy, but the likelihood of failure goes down with the electric replacements. A vac pump going out on a standard plane (and losing *all* bank except TC) is "unpleasant" and not that uncommon. Change 2 out of 3 bank instruments to be electric, rather than vacuum and one failure isn't nearly so bad. -Cory -- ************************************************** *********************** * Cory Papenfuss * * Electrical Engineering candidate Ph.D. graduate student * * Virginia Polytechnic Institute and State University * ************************************************** *********************** |
Thread Tools | |
Display Modes | |
|
|
![]() |
||||
Thread | Thread Starter | Forum | Replies | Last Post |
Wet vs Dry Vacuum Pump | Fastglasair | Owning | 7 | December 17th 04 11:46 PM |
Wet vs Dry Vacuum Pump | Fastglasair | Home Built | 1 | December 15th 04 05:17 PM |
Backup vacuum pump system STC'ed for Cherokee 180 | Chuck | Owning | 6 | September 18th 04 02:30 PM |
Reverse Vacuum Damging to Instruments? | O. Sami Saydjari | Owning | 8 | February 16th 04 04:00 AM |
Can vacuum AI be removed if a certified electric one is installed?? | Dave | Owning | 11 | January 12th 04 06:08 PM |