#1
|
|||
|
|||
![]()
Matt Barrow wrote:
"Roger (K8RI)" wrote in message Over 20 years ago I had the chance to tour the pumping and fuel distribution control facility at a refinery. *Everything* was controlled from that room. They measured flow rates Vs time and claimed they could control the flow to the remote storage facilities hundreds of miles away within several gallons. the system was automated. The operator told it how many gallons of what to go where. Different mixes and fuels were sent through the same pipeline with no one on the other end to either make the switch or to monitor it. Were it only that the ATC system was so automatic, instead of so antiquated. And about 15 years ago, the operators at the storage facilities in Greensboro, NC were fined heavily for leaking fuels into ground water. They tried to claim they didn't know it was happening. Disk jockeys at the time were making fun of the fact that they pump would meter out gas to the hundredth of a gallon, but they couldn't keep track of the thousands that were pouring into the groundwater. 8*) Greensboro is my hometown. |
#2
|
|||
|
|||
![]()
The operator told it how many gallons of what to go
where. Different mixes and fuels were sent through the same pipeline with no one on the other end to either make the switch or to monitor it. Is there no diffusion at the boundaries? Jose -- You can choose whom to befriend, but you cannot choose whom to love. for Email, make the obvious change in the address. |
#3
|
|||
|
|||
![]()
Jose writes:
Is there no diffusion at the boundaries? There is some. How much is complex. It depends on what the two products are, the rate, and a big issue, is the line kept tight? By tight I mean, was it running non-stop at the same backpressure the whole time? If the line went up & down in rate because they added pumps or swung to a different tank, then there is a longer [time] or broader [linear feet of product] mix region. Some lines actually used spheres between, but they bring their own problems... For a real mess; picture a midline booster pump, only used for some products. You must keep track of what product is now in the booster station line section before you restart. No fair dumping Diesel or Kero into the gas going by.... but the opposite is OK. [Too much gas in the distillate is Not Allowed, but a bbl or 3 in a 100,000 bbl tank is no big deal.] -- A host is a host from coast to & no one will talk to a host that's close........[v].(301) 56-LINUX Unless the host (that isn't close).........................pob 1433 is busy, hung or dead....................................20915-1433 |
#4
|
|||
|
|||
![]() "David Lesher" wrote Some lines actually used spheres between, but they bring their own problems... A little further OT,... I've watched a lot of heavy #6 (needs to be heated to pump) unloaded at the offshore platform. When the tanker is empty, we pig the pipe and backfill with #2. The methods seem crude to the observer, but the results are exact enough even for the accountants. |
#5
|
|||
|
|||
![]() He may cut early. middle or late; it depends on the two products. The schedulers try to make adjacent 'tenders' friendly. Interesting post. Thanks Dave Paul N1431A KPLU |
|