Hello all!

I have an infrequent problem with my Acrosport 2 that I can't seem to
solve. Sometimes during rolls, inverted flight and some times spins
the engine will quit. I always get it to start right back up after a
few seconds. It seems like I usually have to change my throttle
setting to get it to start again but that might just be a timing
coincidence. I put a new flop tube in the tank late last year and
started flying with my aux fuel pump always on and I thought I had it
fixed. But then I was flying with a friend last week with a little
less than 1/2 a tank and it quit twice on me. The fuel system seems
clean.

System: Inverted 13" flop tube system, 25 gallon tank, no header
tank, Christian inverted oil system, Bendix fuel injector.

Do you guys always fly with full fuel?

Is unporting somewhat common on flop tube systems?

Anything else I am missing?

Thanks a million!
Bob
232BS "Over Easy"

  #2  
Old June 13th 06, 05:10 PM posted to rec.aviation.aerobatics
external usenet poster
 
Posts: n/a
Default Fuel Unporting


over easy wrote:
Hello all!

I have an infrequent problem with my Acrosport 2 that I can't seem to
solve. Sometimes during rolls, inverted flight and some times spins
the engine will quit. I always get it to start right back up after a
few seconds. It seems like I usually have to change my throttle
setting to get it to start again but that might just be a timing
coincidence. I put a new flop tube in the tank late last year and
started flying with my aux fuel pump always on and I thought I had it
fixed. But then I was flying with a friend last week with a little
less than 1/2 a tank and it quit twice on me. The fuel system seems
clean.

System: Inverted 13" flop tube system, 25 gallon tank, no header
tank, Christian inverted oil system, Bendix fuel injector.

Do you guys always fly with full fuel?

Is unporting somewhat common on flop tube systems?

Anything else I am missing?

Thanks a million!
Bob
232BS "Over Easy"


 




Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump

Similar Threads
Thread Thread Starter Forum Replies Last Post
Time, running out of fuel and fuel gauges Dylan Smith Piloting 29 February 3rd 08 08:04 PM
I want to build the most EVIL plane EVER !!! Eliot Coweye Home Built 237 February 13th 06 04:55 AM
Most reliable homebuilt helicopter? tom pettit Home Built 35 September 29th 05 02:24 PM
Mini-500 Accident Analysis Dennis Fetters Rotorcraft 16 September 3rd 05 11:35 AM
Is Your Airplane Susceptible To Mis Fu eling? A Simple Test For Fuel Contamination. Nathan Young Piloting 4 June 14th 04 06:13 PM


All times are GMT +1. The time now is 06:04 AM.


Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 AviationBanter.
The comments are property of their posters.