View Single Post
  #7  
Old December 16th 04, 08:56 PM
Denny
external usenet poster
 
Posts: n/a
Default

I just put a new heater in Fat Albert from C&D, to replace the
Southwind... Test flew it yesterday for the first time... 28F outside,
and I had to keep turning down the heat inside - halfway open on the
knob was just right... On that point I'm a happy camper...

The old heater was working but had an AD for inspection every 500 hours
(531 in the logbook since last inspection)... Pulled it and found a
tiny crack on the can, plus it had been welded before (no entry in the
logs)... Called three major shops for opinions and they were uniform
that it needed to be zero timed which would be $1800 plus my obsolete
solenoid/fuel regulator had to go, for another $650... In the end I
sprang for brand new unit with a warranty... That turned out to be
$3200 with shipping, plus a number of hours of labor to install a new
control switch and wiring... At least I have no AD's for now...
Denny and Fat Albert