Paul Remde
external usenet poster
 
Posts: 1,691
Default Volkslogger help

Hi Glen,

The error mentioned below may be simply that the communication port on the
PDA is already in use by another application. Try doing a soft reset to the
PDA immediately before running ConnectMe.

If the VL is powered by the SN10 (which is likely), then when you power-down
the SN10 you also power-down the VL - so it is rebooted.

What logging interval is set on the VL?

Is the VL memory cleared immediately before flight?

Those are the only things that come to mind.

Best Regards,

Paul Remde
Cumulus Soaring, Inc.

"Laura betzoldt" wrote in message
...
Volkslogger shuts down after about 15 min into flight, can turn off
and on ILEC sn-10 and volks will start working again. Can’t down
flight from Volks to PDA with see you mobile. I get ERROR OCCURRIED
COMMUNICATION WITH/DEVICE EXTERNAL CODE (-10) on Connect Me.
Just had Volks calibrated??
Any
ideas